The 2792 series boards are designed for high speed applications. The standard converter is +/- 3 arc
minutes. The maximum tracing rate is a function of the excitation frequency and quadrature counts. With a 10 kHz excitation and 4096 quadrature counts per cycle the maximum tracking rate would be 28,000 rpm.
With a 10.0 kHz excitation and 8192 quadrature counts the maximum tracking rate would be 14,000 rpm.
|